SKU: SVT30KX Categories: , Brand: Tripp Lite Tag:

Tripp Lite SmartOnline SVTX Series 3-Phase 380/400/417V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option - SVT30KX

  • Order Now. Speak to a Specialist. Call 0800 978 8988.
  • ETA will be advised upon ordering or call us on 0800 978 8988 for leadtime.

Tailor to your needs. Speak to a Specialist.
Call: 0800 978 8988

  • Description
    VFI True On-Line Double-Conversion 3-Phase UPS System
    • Provides fully regulated sine wave AC output for critical telecom, network, security, financial, corporate and light industrial applications
    • +/-1% output voltage regulation in online and battery modes
    • High 0.9 power factor offers 30kVA/27kW output capacity, allowing for more connected devices
    • Selectable 380/400/417V output voltage
    • Wide input voltage windowimizes battery use and prolongs battery life
    Reliable Battery Backup with Expandable Runtime
    • Supports half load for 10 and full load for 4 .
    • Zero transfer time suitable for advanced network applications
    • Expandable runtime with optional external battery packs, such as Tripp Lite?s BP240V175
    • Restarts automatically after lengthy power outages
    IGBT Inverter Technology
    • Produces output power with less than 2% THD to keep connected equipment functioning at its peak
    • Low <6% THDi input rating and advanced IGBT rectifier enables 1:1 Generator Sizing, eliating costly oversizing requirements for generators, breakers and cables
    Paralleling Capability
    • Connect up to 3 units in parallel configuration for increased capacity
    Automatic and Manual Bypass
    • Increases system reliability
    • Allows maintenance without removing power from attached loads
    ECO Mode
    • Operates at efficiency levels as high as 98.8% when input line conditions are favorable
    SNMP/Web Capability
    • Slot for WEBCARDLX network interface or RELAYCARDSV relay card for remote monitoring and control options
    • Optional WEBCARDLXwith the latest version of PowerAlert Device Manager firmwareprovides enhanced remote management capabilities
    • PADM20 and PowerAlert Element Managerform a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
    Communications Ports
    • DB9 and EPO ports offer local monitoring and shutdown options
    Small-Footprint Tower Design
    • Reduced-size black tower case saves valuable floor space
    • Matching external battery cabinets enable extended runtime options

  • Technical Data
    OVERVIEW
    UPC Code037332192462
    UPS TypeOn-Line
    INPUT
    Rated input current (Maximum Load)48.9A
    Nominal Input Voltage(s) Supported220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
    Nominal Input Voltage Description3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G)
    UPS Input Connection TypeHardwire
    Input Circuit Breakers63A (3 pole)
    Input Phase3-Phase
    Power Factor (Input)  .99PF (100% load)
    THDi  <6% (100% load)
    OUTPUT
    Output Volt Amp Capacity (VA)30000
    Output Capacity (kVA)30
    Output Watt Capacity (Watts)27000
    Output kW Capacity (kW)27
    Output Capacity DetailsSupports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to 70% or less; Configuration options support up to 3 SVT30KX systems wired in parallel for increased capacity.
    Power Factor  0.9
    Crest Factor  3:1
    Frequency Compatibility50 / 60 Hz
    Frequency Compatibility DetailsAutomatic frequency selection
    Output Voltage Regulation (Line Mode)+/- 1%
    Output Voltage Regulation (Economy Line Mode)+/-11V of selected nominal output voltage (220V: 209-231V; 230V: 219-241; 240V: 229-251V)
    Output Voltage Regulation (Battery Mode)+/- 2%
    Output AC Waveform (AC Mode)Pure Sine wave
    Output AC Waveform (Battery Mode)Pure Sine wave
    Nominal Output Voltage(s) Supported220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
    Output ReceptaclesHardwire
    Individually Controllable Load Banks  No
    BATTERY
    Full Load Runtime (min.)  4.2 min (27kW)
    Half Load Runtime (min.)  9.6 min. (13.5kW)
    Expandable Battery RuntimeSupports extended runtime optional external battery packs
    Expandable RuntimeYes
    External Battery Pack Compatibility   BP240V135 
    DC System Voltage (VDC)240
    Battery Recharge Rate (Included Batteries)4 hours to 90% (Internal batteries)
    VOLTAGE REGULATION
    Voltage Regulation DescriptionOnline, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode
    Overvoltage Correction  Corrects overvoltage conditions to 520V (50% load) and 478V (100% load)
    Undervoltage Correction  Corrects brownout conditions to 110V (50% load) / 305V (100% load)
    USER INTERFACE, ALERTS & CONTROLS
    Front Panel LCD DisplayLCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage & frequency, estimated runtime and more (see user manual for a detailed listing)
    SwitchesON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information)
    Audible AlarmAlarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD & OTHER WARNINGS conditions
    LED Indicators4 LEDs report BYPASS / LINE / BATTERY / FAULT modes
    PHYSICAL
    Primary Form FactorTower
    Cooling MethodFans
    Installation Form Factors Supported with Included AccessoriesTower
    Primary UPS Depth (mm)300
    Primary UPS Height (mm)998
    Primary UPS Width (mm)813
    Shipping Dimensions (hwd / cm)124.00 x 43.00 x 92.00
    Shipping Weight (kg)255.00
    UPS Housing MaterialSteel
    UPS Power Module Dimensions (Height x Width x Depth, mm)1000 x 300 x 813
    UPS Power Module Dimensions (hwd, cm)99.82 x 81.28 x 30.00
    UPS Power Module Weight (kg)233.60
    ENVIRONMENTAL
    Operating Temperature Range0 to +40C (32-104F)
    Storage Temperature Range0 to +35C (32 to 95F) with battery; -15 to 60C (5 to +140F) without battery
    Relative Humidity5 to 95%, non-condensing
    AC Mode BTU / Hr. (Full Load)  9120
    Operating Elevation (ft.)< 3000ft (Capacity de-rates by 1% for every 330ft over 3000)
    Audible Noise<65dBA front side 1M
    Operating Elevation (m)< 1000m (Capacity de-rates by 1% for every 100m over 1000)
    COMMUNICATIONS
    Network Management Cards WEBCARDLX ;  MODBUSCARDSV ;  RELAYCARDSV 
    Network Monitoring Port DescriptionCard accessory slot also supports network interface and relay card options
    Communications CableDB9 cabling included
    Communications InterfaceDB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
    LINE / BATTERY TRANSFER
    Transfer Time  Zero transfer time in ONLINE MODE (0ms); ECONOMY MODE: 7ms from AC to Battery mode / 0.6ms from Battery to AC mode
    Low Voltage Transfer to Battery Power (Setpoint)110V (50% load) / 305V (100% load)
    High Voltage Transfer to Battery Power (Setpoint)520V (50% load) / 478V (100% load)
    FEATURES & SPECIFICATIONS
    Grounding LugYes
    Cold Start (Startup in Battery Mode During a Power Failure)Cold-start operation supported
    High Availability UPS Features  Automatic inverter bypass; Manual bypass switch; Auto Probe Monitoring (requires WEBCARDLX); Zero transfer time; On-Line/Double-Conversion
    Green Energy-Saving FeaturesHigh efficiency economy mode operation
    STANDARDS & COMPLIANCE
    UPS CertificationsCE
    Certification DetailsEN 62040-1-1 (Safety); EN 62040-2 (Category C3)
    WARRANTY
    Product Warranty Period (International)2-year limited warranty
    3-Phase Warranty StatementTripp Lite 3-Phase UPS Factory Warranty
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

  • Downloads

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us