SKU: SVX180KL Categories: , Brand: Tripp Lite Tag:

Tripp Lite SmartOnline SVX Series 180kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System - SVX180KL

  • Order Now. Speak to a Specialist. Call 0800 978 8988.
  • ETA will be advised upon ordering or call us on 0800 978 8988 for leadtime.

Tailor to your needs. Speak to a Specialist.
Call: 0800 978 8988

  • Description
    • Tripp Lite’s SVX180KL 180kVA / 180kW SmartOnline UPS offers network-grade power protection in a highly-configurable large-chassis modular, scalable form factor
    • Supports 220/380, 230/400 or 240/417V AC, 3-Phase Wye 4-Wire plus Earth Hardwire input and output wiring
    • Tested to CE for worldwide applications
    • Open slots for up to 2 additional SVX30PM 30kW power modules enables scalable capacity configurations up to 210kW with enhanced N+1 reliability
    • Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmwareprovides enhanced remote management capabilities
    • PADM20 and PowerAlert Element Managerform a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
    • Serial port enables unattended shutdown and UPS monitoring ability
    • Modular configuration with hot-swappable power modules enables easy and fast maintenance with zero downtime
    • Wide input voltage operating range enables full continuous online operation during brownouts as low as 160Vand overvoltages up to 276
    • Narrow output voltage operating range regulates output voltage within 1% of the selected 220/230/240 noal output voltage in online, double-conversion mode
    • Over 95% efficient in online, double-conversion mode and over 99% efficient in optional economy-mode enables reduced operating and cooling costs
    • Less than 3% input Total Harmonic Distortionprevents the need to oversize generator systems relative to UPS capacity
    • Dual hardwire input design enables operation from one or two input power sources
    • N+1 fault tolerance is supported anytime there is an ?extra? SVX30PM 30kW power module installed beyond the imum required quantity
    • Front panel combination LCD/LED display offers full UPS condition and status reporting plus additional configuration options

  • Technical Data
    OVERVIEW
    UPC Code037332192561
    UPS TypeOn-Line
    INPUT
    Rated input current (Maximum Load)SVX180KL 180kVA Configuration: 330A; Maximum 210kVA Large Chassis Configuration: 385A; 40A maximum inrush current
    Nominal Input Voltage(s) Supported220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
    Nominal Input Voltage DescriptionSet of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, G) inputs from two separate power sources
    UPS Input Connection TypeHardwire
    Input Circuit BreakersMAIN and ALTERNATE AC inputs are each protected by 400A 3 pole magnetic breakers
    Input Phase3-Phase
    Input Frequency40 to 70Hz (online mode); 50/60Hz Auto-selectable
    Power Factor (Input)  Greater than 0.99 (full load)
    THDi  Less than 3% (full linear load)
    OUTPUT
    Output Volt Amp Capacity (VA)180000
    Output Capacity (kVA)180
    Output Watt Capacity (Watts)180000
    Output kW Capacity (kW)180
    Output Capacity DetailsOVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less
    Power Factor  1.0
    Crest Factor  3:1
    Nominal Voltage DetailsOutput THD full resistive load: <1.5%; Output THD non-linear load: <4%; Max DC offset: ±50mV; Max Phase angle deviation: 2°; Max Voltage unbalance deviation: 1%; Output short-circuit protection included
    Frequency Compatibility50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
    Frequency Compatibility DetailsAuto-selectable, user adjustable
    Output Circuit Breakers400A 3 pole magnetic breaker
    Output AC Waveform (AC Mode)Pure Sine wave
    Output AC Waveform (Battery Mode)Pure Sine wave
    Nominal Output Voltage(s) Supported220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
    Output ReceptaclesHardwire
    Output Voltage Regulation  ONLINE, FREQUENCY CONVERSION, BATTERY MODE: 220/230/240V ±1% typical (balanced load); ±2% typical (unbalanced load); ECONOMY MODE: 220/230/240V ±15V; BYPASS MODE: +15% (default, adjustable to +10%, +15% or +20%), -20% (default, adjustable to -10%, -20%, -30%)
    Output Frequency Regulation  ONLINE MODE: Output frequency is ±0.05Hz of input frequency when input is within ±4Hz* of the configured 50/60Hz output setting; Output frequency is ±0.05Hz the configured 50/60Hz output setting when input is outside ±4Hz* of the configured 50/60Hz output setting; BATTERY MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; FREQUENCY CONVERTER MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; ECONOMY MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (UPS switches to Online mode if frequency goes outside of this range); BYPASS MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (switches to STANDBY mode if frequency goes outside of this range). *The TRACKING RANGE is factory set to ±4Hz and is user adjustable to ±1Hz, ±2Hz or ±4Hz; The selected TRACKING RANGE setting controls frequency output tolerances as described above in Online, Economy and Bypass modes
    Output Amp CapacityOutput Amp Capacity 273A (220/380V); 260A (230/400V); 250A (240/415V)
    Individually Controllable Load Banks  No
    Modular Upgrade OptionsIncludes 6 SVX30PM 30kVA power modules. Up to 2 additional SVX30PM 30kVA power modules can be added for additional capacity or N+1 availability; Add 1 SVX30PM for 210kVA capacity (or 180kVA with N+1 redundancy); Add 2 SVX30PM for 210kVA capacity with N+1 redundancy
    BATTERY
    Full Load Runtime (min.)  Batteries sold separate; Runtime is dependent on battery pack quantity and load level
    Expandable Battery RuntimeSupports extended runtime with optional external battery packs; 100A 3 pole 250VDC breaker recommended for external battery
    Expandable RuntimeYes
    Expandable Runtime DescriptionExternal battery pack wiring is contractor supplied
    DC System Voltage (VDC)±240VDC
    Battery Recharge Rate (Included Batteries)User selectable charging current of 1A to 8A (2A factory setting); Recharge rate is dependent on number of external battery packs connected and the selected charge current setting
    Battery Replacement DescriptionHot-swappable, replaceable batteries
    VOLTAGE REGULATION
    Voltage Regulation DescriptionOnline, double-conversion power conditioning
    Overvoltage Correction  Maintains continuous output in online mode, without using battery power, during overvoltages to 478V (Ph-Ph), reducing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage
    Undervoltage Correction  Maintains continuous output in online mode, without using battery power, during brownout/undervoltage conditions to 305V (Ph-Ph) at full load and to 208V (Ph-Ph) at 70% output load or less, increasing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage
    USER INTERFACE, ALERTS & CONTROLS
    Front Panel LCD Display145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions
    SwitchesFront panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch
    Alarm Cancel OperationAudible alarms can be muted using on-screen prompts
    Audible AlarmUnique audible alarms for POWER ON / POWER OFF (alarm sounds for 2 seconds), BATTERY MODE (alarm sounds every 2 seconds), LOW BATTERY (alarm sounds every 0.5 seconds), UPS ALARM (alarm sounds every 1 second), UPS FAULT (continuous alarm)
    LED IndicatorsFront panel LED indicators represent INPUT (green), BYPASS (amber), INVERTER (green), BATTERY (red) and ALARM (red)
    SURGE / NOISE SUPPRESSION
    EMI / RFI AC Noise Suppression  Yes
    AC Suppression Joule Rating  2496
    AC Suppression Joule Rating Details2496 joules (Ph-E), 2496 joules (Ph-N), 1872 joules (N-E)
    AC Suppression Response Time  Instantaneous
    PHYSICAL
    Primary Form FactorTower
    Cooling MethodFans
    Installation Form Factors Supported with Included AccessoriesTower
    Primary UPS Depth (mm)1,100
    Primary UPS Height (mm)2,010
    Primary UPS Width (mm)600
    Shipping Dimensions (hwd / cm)217.47 x 74.98 x 122.00
    Shipping Weight (kg)478.54
    UPS Housing MaterialSteel
    UPS Power Module Dimensions (hwd, cm)200.99 x 59.99 x 109.98
    UPS Power Module Weight (kg)479.90
    ENVIRONMENTAL
    Operating Temperature Range0° to +40°C (+32° to +104°F); De-rates to 90% capacity at 35°C / 95°F and 80% capacity at 40°C / 104°F
    Storage Temperature Range-15° to +60°C (+5° to +140°F)
    Relative Humidity0 to 95%, non-condensing
    AC Mode BTU / Hr. (Full Load)  33166
    AC Economy Mode BTU / Hr. (Full Load)5078
    AC Mode Efficiency Rating (100% Load)95%
    AC Economy Mode Efficiency Rating (100% Load)99%
    Audible NoiseAudible Noise Less than 73 DBA front-side, 1m
    Operating Elevation (m)Operating Elevation (m) Up to 1000m (At elevations over 1000m, output de-rates by 1% per 100m)
    COMMUNICATIONS
    Network Management Cards WEBCARDLX ;  MODBUSCARDSV ;  RELAYCARDSV 
    Network Monitoring Port DescriptionIncludes pre-installed Tripp Lite WEBCARDLX network interface
    PowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
    Communications CableDB9 cabling included
    SNMP CompatibilitySNMP Compatibility Includes pre-installed  WEBCARDLX  network interface card
    Communications InterfaceDB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface
    LINE / BATTERY TRANSFER
    Transfer Time  No transfer time (0 ms.) in online, double-conversion mode; Less than 20 ms. transfer time in economy mode
    Low Voltage Transfer to Battery Power (Setpoint)Maintains continuous operation without using battery power during brownout/undervoltage conditions to 305V (Ph-Ph) Full load or 208V (Ph-Ph) 70% load or less; Below the low transfer voltage point, output is maintained utilizing reserve battery power
    High Voltage Transfer to Battery Power (Setpoint)Maintains continuous operation without using battery power during overvoltages to 478V (Ph-Ph), reducing output within 1% of nominal; Above this point, output is maintained utilizing reserve battery power
    FEATURES & SPECIFICATIONS
    Cold Start (Startup in Battery Mode During a Power Failure)Cold-start operation supported
    High Availability UPS Features  Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Auto Probe Monitoring (included); Zero transfer time; On-Line/Double-Conversion
    Green Energy-Saving FeaturesGreater than 95% efficiency – GREEN UPS; High efficiency economy mode operation; Schedulable daily hours of economy mode operation
    STANDARDS & COMPLIANCE
    UPS CertificationsCE; ROHS (Restriction of Hazardous Substances)
    Certification DetailsAgency standards IEC 62040-1:2008+A1:2013; EMI Approvals EN62040-2, 2006 (Category C3); Vibration and Shock: SS-EN 60068-2-64
    WARRANTY
    Product Warranty Period (International)2-year limited warranty
    3-Phase Warranty StatementTripp Lite 3-Phase UPS Factory Warranty
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

  • Downloads
    SVX180KL runtime chart Conduit Box Installation Instructions (Multi-language) Instruction Sheet for PowerAlert® Mass Updater Utility (English) Instruction Sheet for Tripp Lite Networked Device Mass Configuration Utility (English) LX Firmware Update Instructions (English) Owner's Manual for SmartOnline® 400V SVX-Series 3-Phase Modular UPS Systems (Multi-language) User's Guide for WEBCARDLX PowerAlert Device Manager (English) PowerAlert Device Manager (PADM) 20.0.0 Command Line Interface User's Guide (English) User's Guide for PowerAlert Network Management System (PANMS) (English) Owner's Manual for WEBCARDLX (English) Owner's Manual for WEBCARDLX (Multi-language) User's Guide for PowerAlert Network Shutdown Agent PANSA (English) PowerAlert Device Manager (PADM) 20.0.0 Command Line Interface PowerAlert Device Manager (PADM) 20.0.0 3-Phase UPS Systems Visio Stencil 3-Phase UPS Systems Visio Stencil Preview SV Series 400V Large Frame Submittal Drawing Submittal Drawings SmartOnline SVX 3-Phase UPS System Brochure (English) SNMP Management of Tripp Lite Devices Technical Application Bulletin (English)

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us