Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988

Vertiv Liebert aps 16-bay frame 1-phase 5kVA with 2 internal battery strings 8-10y - AS2A0NCMMNNX000

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups

    Tailor to your needs. Speak to a Specialist.
    Call: 0800 978 8988

    In Stock — 1 available to order

    Need a quote?

    The Vertiv APS UPS provides mission-critical aVAilability ensuring your critical IT functions and your business will be available and running as expected through power disruptions, fluctuations and outages.

    The Vertiv APS UPS adapts efficiently and effectively as the needs of your users and core business power requirements change. The UPS offers capacity on demand with FlexPower core modules allowing you to change capacity in 5kVA/4.5kW increments up to 20kVA.

    – True On-line double conversion UPS
    – Transformer-free and transformer-based models
    – User installable, hot-swappable capacity and battery modules
    – Internal redundancy capability (N+2/20kVA)

    Low Total Cost of Ownership

    – Industry-leading efficiency: 92% for transformer-free systems and up to 89.9% for transformer based systems.
    – Scalability that allows you to cost-effectively add power capacity or battery modules as needed.
    – Modular batteries, controls and power components to help reduce maintenance costs with user replacement.
    – Two year hassle-free factory warranty program for repair or replacement of your Vertiv APS UPS.
    – Module-level redundancy eliminates the expense of purchasing and planning for additional cabinets.
    – Reduced installation time and cost because units are shipped pre-configured and factory tested, no need for on-site assembly.
    – Everything you need for efficiency and aVAilability in one box: power modules, batteries, maintenance bypass, and distribution in a single, SMAll-footprint cabinet.
    – Integral battery monitoring with temperature compensated charging to prolong battery life and help reduce replacement costs.

    Reliability and Serviceability

    – Internal redundancy capability (N+2/20kVA) enhances reliability and provides multiple layers of power protection.
    – No single point of failure – Full redundant design allows the critical load to run on conditioned power if there is a failure of any component in the system.
    – Configurable design allows you to customize the Vertiv APS UPS for your desired level of capacity and redundancy.
    – Fault-tolerant design, enables the power, battery and control modules to take themselves offline if there is a problem, without sacrificing overall system integrity.
    – Superior overload capabilities, able to provide conditioned power to temporary overloads without transfers to/from bypass power.
    – Internal wrap-around maintenance bypass and frame-level bypass with independent controls in separate assembly provide higher reliability and aVAilability.

    Flexibility

    – Capacity on demand with FlexPower core modules that allow you to change capacity as needed in 5 kVA/4.5 kW increments – without powering down.
    – More real kW – 0.9 power factor provides more real power to support the I.T. load than other solutions in this size range.
    – Isolated and non-isolated models to provide the right solution for your power protection needs.
    – Integrated distribution PODs allow selection of a VAriety of distribution options to meet application requirements.
    – Trellis platform connectivity, so the Vertiv APS can easily be integrated with this robust, real-time data center optimization solution.
    – Three Vertiv Intellislot ports allow integration and communication with a VAriety of infrastructure management solutions, leading to better power optimization and visibility.
    – Optional matching external battery cabinets provide longer battery run times to protect against sustained power issues.
    – Installation Flexibility use on raised floors, traditional flooring, or in rack enclosures.
    – Large input voltage window, which minimizes transfer to battery and increases battery life; low line transfer can range down to 110v.
    – Wide range of use, with the ability to be installed on raised floors, traditional flooring, or in rack enclosures

    Ideally Suited For

    – SMAll-to-medium-sized data centers
    – Network closets
    – VoIP

    Power
    Output voltage regulation 3%
    Input power factor 0.99
    Output power 5000 W
    Input operation voltage (min) 140 V
    Input operation voltage (max) 485 V
    Output operation voltage (min) 200 V
    Output operation voltage (max) 240 V
    Power factor 0.9
    Output power capacity 5000 VA
    Efficiency (On-line mode) 92%
    Three-phase input voltage supported 380,400,415 V
    Single-phase input voltage supported 220,230,240 V
    Performance
    UPS topology Double-conversion (Online)
    Waveform Sine
    Number of output phases 1
    Number of input phases 1/3
    LED indicators Yes
    Noise level 65 dB
    Overload capacity (1 minute) 130%
    Features
    Output frequency 50/60 Hz
    UPS topology Double-conversion (Online)
    Waveform Sine
    Output voltage regulation 3%
    Number of output phases 1
    Number of input phases 1/3
    Input power factor 0.99
    Output power 5000 W
    Input operation voltage (min) 140 V
    Input operation voltage (max) 485 V
    Output operation voltage (min) 200 V
    Output operation voltage (max) 240 V
    Power factor 0.9
    Noise level 65 dB
    Output power capacity 5000 VA
    Overload capacity (1 minute) 130%
    Efficiency (On-line mode) 92%
    Three-phase input voltage supported 380,400,415 V
    Single-phase input voltage supported 220,230,240 V
    Input frequency 50/60 Hz
    Ports & interfaces
    USB port Yes
    AC outlet types Terminal
    Power plug Terminal
    USB 2.0 ports quantity 1
    Serial ports quantity 1
    Battery
    Battery capacity 9 VAh
    Number of batteries supported 12
    Battery voltage 12 V
    Battery technology Sealed Lead Acid (VRLA)
    Number of battery cells 2
    Battery recharge time 5 h
    Typical backup time at half load 30 min
    Typical backup time at full load 5 min
    Hot-swap battery Yes
    Design
    International Protection (IP) code IP20
    Form factor Tower
    LED indicators Yes
    Product colour Black
    Safety IEC62040-1:2008 version & UL/cUL
    Energy Star certified Yes
    Display LCD
    Cooling type Active
    Certification CE
    RoHS compliance Yes
    Operational conditions
    Operating temperature (T-T) 0 – 40 C
    Storage temperature (T-T) -20 – 60 C
    Operating relative humidity (H-H) 0 – 95%
    Storage relative humidity (H-H) 0 – 95%
    Operating altitude 0 – 3000 m
    Non-operating altitude 0 – 3000 m
    Technical details
    Output voltage 230 V
    Output frequency 50/60 Hz
    Cooling
    Cooling type Active
    Weight & dimensions
    Weight 222 kg
    Width 440 mm
    Height 970 mm
    Depth 850 mm
    Package width 650 mm
    Package depth 1150 mm
    Package height 1200 mm
    Package weight 232 kg
    Packaging data
    Package width 650 mm
    Package depth 1150 mm
    Package height 1200 mm
    Package weight 232 kg
    Certificates
    Safety IEC62040-1:2008 version & UL/cUL
    Energy Star certified Yes
    Certification CE
    RoHS compliance Yes
    Other features
    Output voltage 230 V

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us