SKU: EXS102C0030A0A0 Categories: , , , Tag:

Vertiv Liebert exs 10kVA 50min autonomy with 10y batteries - EXS102C0030A0A0

Find out how you can order below

How to buy

  • Description

    The new Vertiv EXS is a monolithic transformer-free UPS which brings exceptional features for mission-critical applications. Its extraordinary double conversion efficiency up to 96.2% ensures remarkable operational cost savings, reducing both the Total Cost of Ownership (TCO) and the environmental impact. At the same time, with its unity output power factor and high power density, Vertiv EXS is able to provide the utmost active power possible in a compact footprint. In fact, its improved design reduces its footprint to a minimum, providing continuous power protection with optimized internal runtime in a standalone solution, making the Vertiv EXS perfect for both IT installations and other mission critical applications, such as transportation, emergency lighting, healthcare, retail and government facilities.

    – Reliable and flexible secure power in a fully integrated compact solution
    – Double conversion efficiency up to 96.2%
    – ECO mode efficiency up to 99%
    – Unity output power factor
    – Input current total harmonic distortion correction (THDi) < 3%
    – Integrated manual bypass and input and output breakers/switches

  • Technical Data
    Power
    Output voltage regulation96.2%
    Output frequency regulation50/60 Hz
    Output power10000 W
    Input operation voltage (min)173 V
    Input operation voltage (max)498 V
    Maximum current13 A
    Output voltage Total Harmonic Distortion (THD)2%
    Input current Total Harmonic Distortion (THD)3%
    Output power capacity10000 VA
    Performance
    UPS topologyDouble-conversion (Online)
    Number of input phases3
    Noise level58 dB
    Overload capacity (1 minute)150%
    Features
    UPS topologyDouble-conversion (Online)
    Output voltage regulation96.2%
    Output frequency regulation50/60 Hz
    Number of input phases3
    Output power10000 W
    Input operation voltage (min)173 V
    Input operation voltage (max)498 V
    Maximum current13 A
    Output voltage Total Harmonic Distortion (THD)2%
    Noise level58 dB
    Input current Total Harmonic Distortion (THD)3%
    Output power capacity10000 VA
    Overload capacity (1 minute)150%
    Input frequency40/70 Hz
    Battery
    Battery life (max)10 year(s)
    Design
    International Protection (IP) codeIP20
    Form factorCompact
    Product colourBlack
    CertificationEN/IEC/AS 62040-1, EN/IEC/AS 62040-2, VFI-SS-111
    Technical details
    BypassBypass voltage tolerance (%) +20 – -40
    Bypass frequency tolerance (%) 20 (10 selectable)
    Weight & dimensions
    Width335 mm
    Height1300 mm
    Depth650 mm
    Certificates
    CertificationEN/IEC/AS 62040-1, EN/IEC/AS 62040-2, VFI-SS-111
    Other features
    BypassBypass voltage tolerance (%) +20 – -40
    Bypass frequency tolerance (%) 20 (10 selectable)
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

  • Reviews (0)
    Product Reviews

    Reviews

    There are no reviews yet.

    Be the first to review “Vertiv Liebert exs 10kVA 50min autonomy with 10y batteries”

    Your email address will not be published.

    Company Reviews

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us