    The Vertiv™ Liebert® GXE UPS in an online double conversion single phase UPS which offers power protection in an affordable and efficient system with deployment and operation flexibility. The high output power factor (0.9) of the Liebert GXE UPS enables continuous and reliable power to more connected devices, protecting them against many disturbances in the AC mains with the online double conversion technology. It provides flexibility with either a rack mounting UPS or a in tower form factor, suitable to provide power protection to the critical IT equipment for any application.

    • An affordable and reliable UPS that provides an essential set of features and capabilities such as online double conversion, high output power factor (0.9) or a fast recharge time.
    • Remote monitoring capabilities with the optional network management cards or Vertiv Power Insight free download software.
    • Easy to manage and expand, thanks to its user friendly LCD, hot-swappable user replaceable internal batteries, a flexible rack/tower form factor or the scalable runtime adding external battery cabinets.
    • Optimized energy consumption with its high efficiency in online mode (up to 91%) or the ECO model for even higher efficiency (up to 96%).
    Best Suited For: Banking, Financial and Insurance, Education, Government, Healthcare, Manufacturing, Retail and Wholesale, Telecom, Transportation.
    Technical Specifications
    Model Number GXE3-1000IMT GXE3-1500IMT GXE3-2000IMT GXE3-3000IMT
    Power Rating (VA/W) 1000VA / 900W 1500VA / 1350W 2000VA / 1800W 3000VA / 2700W
    Form Factor Tower Tower Tower Tower
    Dimensions, mm
    Unit (W x D x H) 160 x 315 x 245 160 x 420 x 245 160 x 420 x 245 200 x 425 x 345
    Shipping (W x D x H) 235 x 395 x 325 235 x 560 x 325 235 x 560 x 325 320 x 560 x 460
    Weight, kg
    Unit 11.8 16.4 19.4 27.7
    Shipping 12.5 17.3 20.4 29.3
    Model Number GXE3-1000IRT2UXL GXE3-1500IRT2UXL GXE3-2000IRT2UXL GXE3-3000IRT2UXL
    Power Rating (VA/W) 1000VA / 900W 1500VA / 1350W 2000VA / 1800W 3000VA / 2700W
    Form Factor Rack / Tower (2U) Rack / Tower (2U) Rack / Tower (2U) Rack / Tower (2U)
    Dimensions, mm
    Unit (W x D x H) 438 x 430 x 86 438 x 430 x 86 438 x 430 x 86 438 x 630 x 86
    Shipping (W x D x H) 560 x 600 x 235 560 x 600 x 235 560 x 600 x 235 790 x 600 x 235
    Weight, kg
    Unit 16.0 19.6 22.7 31.5
    Shipping 17.6 21.6 24.8 34.2
    Input AC Parameters
    Voltage Range Without Battery Operation (230V default, derating applies)* 110 – 290 110 – 290 110 – 290 110 – 290
    Voltage Range Without Battery Operation (230V default, 100% load) 180 – 290 180 – 290 180 – 290 180 – 290
    Frequency Range (Hz, autosensing) 40 – 70 40 – 70 40 – 70 40 – 70
    Input Power Connector IEC60320 C14 IEC60320 C14 IEC60320 C20 IEC60320 C20
    Surge Protection (J) 600 600 600 600
    Output AC Parameters
    Output Voltage 220/230 (default) /240 220/230 (default) /240 220/230 (default) /240 220/230 (default) /240
    Waveform Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave
    Output Receptacles 8 x IEC60320 C13 8 x IEC60320 C13 8 x IEC60320 C13 8 x IEC60320 C13 1 x IEC60230 C19
    Efficiency (online mode, max.) 89% 89% 89% 91%
    Efficiency (ECO mode, max.) 95% 95% 96% 96%
    Battery
    Type Valve-regulated, non-spillable, lead-acid Valve-regulated, non-spillable, lead-acid Valve-regulated, non-spillable, lead-acid Valve-regulated, non-spillable, lead-acid
    Recharge Time (internal batteries, typical) <4 hr @ 90% <4 hr @ 90% <4 hr @ 90% <4 hr @ 90%
    Backup Time (100% load, minutes) 3.1 3.2 3.2 3.3
    Backup Time (50% load, minutes) 9 9 9 9.5
    Compatible External Battery Cabinet (RT models only) GXE3-EBC24VRT2U GXE3-EBC36VRT2U GXE3-EBC48VRT2U GXE3-EBC72VRT2U
    Environmental
    Operating Temperature (oC) 0 to 40oC 0 to 40oC 0 to 40oC 0 to 40oC
    Storage Temperature (oC, without battery inside)  -20oC to +50oC -20oC to +50oC -20oC to +50oC -20oC to +50oC
    Relative Humidity (operation, non-condensing) 5% to 95% 5% to 95% 5% to 95% 5% to 95%
    Operating Altitude (m), without derating (**) 2000 2000 2000 2000
    Audible Noise (line mode) <53dBA <53dBA <53dBA <53dBA
    Agency
    Compliance CE, CB Report, UKCA, Morocco, RCM CE, CB Report, UKCA, Morocco, RCM CE, CB Report, UKCA, Morocco, RCM CE, CB Report, UKCA, Morocco, RCM
    Safety IEC/EN 62040-1 IEC/EN 62040-1 IEC/EN 62040-1 IEC/EN 62040-1
    Surge Immunity EN 61000-4-5 EN 61000-4-5 EN 61000-4-5 EN 61000-4-5
    Transportation ISTA 2A ISTA 2A ISTA 2A ISTA 2A
    Environmental RoHS, REACH, WEEE RoHS, REACH, WEEE RoHS, REACH, WEEE RoHS, REACH, WEEE
    Communications and Management
    Slot for optional cards Yes Yes Yes Yes
    Communication port USB USB USB USB
    Emergency Power Off (EPO) Yes Yes Yes Yes
    Warranty
    Warranty (electronics and batteries) 2 years 2 years 2 years 2 years
    (*) Note. Specific conditions or power derating applies.
    (**) Note: up to 3000 m with power derating.

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us