Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988

Vertiv Liebert ps1500rt3-230 uninterruptible power supply (ups) 1500 VA 8 ac outlet(s) line-interactive

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups

    Tailor to your needs. Speak to a Specialist.
    Call: 0800 978 8988

    In Stock — 1 available to order

    Need a quote?

    Vertiv PSI is a compact, line-interactive UPS system designed especially for IT applications such as network closets and SMAll data centers. It provides reliable power protection for servers, critical nodes, network workstations, large network peripherals, network routers, bridges, and other electronic equipment.

    The flexible design of Vertiv PSI allows the UPS to be configured as a self-standing tower or to be rack-mounted within a 2U space. It is available in five capacities, and both 120V or 230V models.

    The UPS features an innoVAtive line-interactive design incorporating buck/boost automatic voltage regulation technology. This protects against utility voltage fluctuation by raising and lowering utility power to the level needed by the connected equipment. It also allows the UPS to prolong battery
    life by maximizing its time on utility power before going to battery.

    Flexibility:
    – Eight battery-backed outlets
    – Configurable input voltage window
    – Rotatable Display Panel
    – Automatic Frequency Sensing
    – Rack Rail Kit
    – Multiple Communications Options: Contact Closure, USB and SNMP

    Ideally suited for:
    – PCs
    – Network workstations
    – Servers
    – Network closets
    – Large network peripherals
    – VoIP

    Higher AVAilability:
    – Data line surge protection
    – AdVAnce early warning of UPS system status
    – Up to five minutes of battery backup time at full load when utility fails
    – Full sequenced battery testing
    – Surge protection
    – Remote emergency power off
    – Hot swappable batteries

    Lowest Total Cost Of Ownership:
    – 0.9 Output Power Factor
    – Wider input voltage window
    – Reduced installation time and costs
    – Warranty Protection

    Power
    Output power 1350 W
    Input operation voltage (min) 165 V
    Surge energy rating 220 J
    Power factor 0.9
    Output power capacity 1500 VA
    Performance
    UPS topology Line-Interactive
    Waveform Sine
    Number of output phases 1
    Number of input phases 1
    Response time 4 ms
    Noise level 45 dB
    Features
    Output frequency 50/60 Hz
    UPS topology Line-Interactive
    Waveform Sine
    Number of output phases 1
    Number of input phases 1
    Response time 4 ms
    Output power 1350 W
    Input operation voltage (min) 165 V
    Surge energy rating 220 J
    Power factor 0.9
    Noise level 45 dB
    Output power capacity 1500 VA
    Input frequency 50/60 Hz
    Ports & interfaces
    USB port Yes
    AC outlets quantity 8 AC outlet(s)
    AC outlet types C13 coupler
    Power plug C14 coupler
    USB 2.0 ports quantity 1
    Serial ports quantity 1
    RS-232 ports 1
    Number of output IEC jumpers 9
    Battery
    Number of batteries supported 3
    Battery voltage 12 V
    Battery capacity 9 Ah
    Battery technology Sealed Lead Acid (VRLA)
    Battery recharge time 5 h
    Typical backup time at half load 9 min
    Design
    International Protection (IP) code IP20
    Form factor Rackmount/Tower
    Product colour Black
    Safety IEC/EN/AS 62040-1-1
    Certification CE
    Operational conditions
    Operating temperature (T-T) 0 – 40 C
    Storage temperature (T-T) -15 – 40 C
    Operating relative humidity (H-H) 0 – 90%
    Storage relative humidity (H-H) 0 – 90%
    Operating altitude 0 – 3000 m
    Technical details
    Output frequency 50/60 Hz
    Sustainability certificates RoHS
    Packaging data
    Package dimensions (WxDxH) 560 x 595 x 228 mm
    Package width 560 mm
    Package depth 595 mm
    Package height 228 mm
    Package weight 24.1 kg
    Weight & dimensions
    Weight 20.9 kg
    Width 440 mm
    Height 88 mm
    Depth 412 mm
    Package width 560 mm
    Package depth 595 mm
    Package height 228 mm
    Package weight 24.1 kg
    Certificates
    Safety IEC/EN/AS 62040-1-1
    Certification CE
    Other features
    Package dimensions (WxDxH) 560 x 595 x 228 mm
    Overload protection Yes
    Nominal output voltage 230 V
    Nominal input voltage 220-240 V

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us