Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988
SKU: a3fb4fbf9a6f Categories: , Brand: Yuasa Tag:

Yuasa 12V 3.2Ah General Purpose VRLA Battery - a3fb4fbf9a6f

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups
  • Order Now. Speak to a Specialist. Call 0800 978 8988.
  • ETA will be advised upon ordering or call us.

£13.00 Ex VAT
£15.6 Inc VAT

Delivery Costs

Find below some of our pricing costs for Critical Power Supplies online store.

England, Wales and Scottish Lowlands

2 to 3 Working Days - £4.99.
Next Working Day - £9.99.
Pre Noon, Pre 10:30am - Contact Us.

Scottish Lowlands Postcodes
AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9

Highlands, Northern Ireland, Channel Islands and Ireland

  • Scottish Highlands
    3 to 5 Working Days - £20

    Scottish Highlands Postcodes
    AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4

  • Northern Ireland
    3 to 5 Working Days - £50

  • Channel Islands
    3 to 5 Working Days - £25

  • Ireland
    5 to 7 Working Days - £99

  • Western Europe
    5 to 7 Working Days - £150 DAP
    DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.

Purchase this item and get 130 Points - equivalent to the value of £0.13

All major debit and credit cards accepted.

Yuasa NP, NPC and NPH Batteries Utilising the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries.

FEATURES

  • Superb recovery from deep discharge.
  • Electrolyte suspension system.
  • Gas Recombination.
  • Multipurpose: Float or Cyclic use.
  • Usable in any orientation (except continuous inverted).
  • Superior energy density.
  • Lead calcium grids for extended life.
  • Manufactured World wide.
  • Application specific designs.

Technical Features

Sealed Construction

Yuasa’s unique construction and sealing technique ensures no electrolyte leakage from case or terminals.

Electrolyte Suspension System

All NP batteries utilize Yuasa’s unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added.

Control of Gas Generation

The design of Yuasa’s NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use.

Low Maintenance Operation

Due to the perfectly sealed construction and the recombination of gasses within the cell, the battery is almost maintenance free.

Terminals

NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown.

Operation in any Orientation

The combination of sealed construction and Yuasa’s unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. (Excluding continuous use inverted)

Valve Regulated Design

The batteries are equipped with a simple, safe low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container.

Specifications
Nominal voltage (V) 12
20-hr rate Capacity to 10.5V at 20C (Ah) 3.2
10-hr rate Capacity to 10.8V at 20C (Ah) 2.9
Dimensions
Length (mm) 134 (1)
Width (mm) 67 (1)
Height over terminals (mm) 64 (2)
Mass (kg) 1.1
Terminal Type
FASTON – Quickfit / release (JST where stated) 4.75
Operating Temperature Range
Storage (in fully charged condition) -20C to +60C
Charge -15C to +50C
Discharge -20C to +60C
Storage
Capacity loss per month at 20C (% approx.) 3
Case Material
Standard ABS (UL94:HB)
FR version available UL94:V0
Charge Voltage
Float charge voltage at 20C (V)/Block 13.65 (1%)
Float charge voltage at 20C (V)/Cell 2.275 (1%)
Float Chg voltage tmp correction factor from std -3
20C (mV)
Cyclic (or Boost) charge Voltage at 20C (V)/Block 14.5 (3%)
Cyclic (or Boost) charge Voltage at 20C (V)/Cell 2.42 (3%)
Cyclic Chg voltage tmp correction factor from std -4
20C (mV)
Charge Current
Float charge current limit (A) No limit
Cyclic (or Boost) charge current limit (A) 0.8
Maximum Discharge Current
1 second (A) 96
1 minute (A) 32
Impedance
Measured at 1 kHz (m?) 50
Design Life & Approvals
EUROBAT Classification: Standard Commercial 3 to 5
Yuasa design life at 20C (yrs) up to 5
VdS (Germany) VdS No: G 118039

Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

Platinum Plus

 

Technical Hotline 24/7 Yes Yes Yes Yes Green tick
Preventative Maintenance Yes Yes Yes Yes Green tick
Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
Firmware Upgrades Yes Yes Yes Yes Green tick
Emergency Response Yes Yes Yes Yes Green tick
Labour Yes Yes Yes Yes Green tick
Parts Yes Yes Yes option Green tick
Monthly Event/Status Report option option option option Green tick
Onsite Crash Kit option option option onsite Green tick
Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
Guaranteed Fix time 4 Clock hours Green tick

3: 24×7 Remote Monitoring Contracts –

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours Green tick
24×7 flexible status and remote monitoring. Green tick
Encrypted communication, allowing safe offsite monitoring Green tick
Alarms and events emailed and SMS texted automatically Green tick
Firewall Friendly Green tick
Cloud based status overview and multiple sites status on one screen Green tick
Allows First Fix Response to Site Green tick

4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

5. Switchgear – Contact us for more information.

Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

  • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
  • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
  • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us