Yuasa YUCEL 12V 2.9Ah General Purpose VRLA Battery - YUCEL 2.9-12
Find out how you can order below
How to buy- Description
The Yucel 12V 2.9Ah VRLA battery from Yuasa is built for multiple uses from Power Management, Portable Devices, Consumer Electronics, Industrial.
Overview
- 20-Hr rate Capacity to 1.75VPC at 20°C – 2.8Ah
- Terminal type – FASTON (Quickfit / release)
- Standard Case Material – ABS (UL.94:HB)
- Eurobat classification – 3 to 5 years
- Battery Weight – 1.1Kg
- Technical Data
SPECIFICATIONS Nominal voltage 12 V 20-hr rate Capacity to 1.75VPC at 20C 2.9 Ah 10-hr rate Capacity to 1.75VPC at 20C 2.7 Ah DIMENSIONS Length 79 (1) mm Width 56 (1) mm Height 99 (1) mm (height over terminals) 105 (2) mm Mass (typical) 1.1 kg TERMINAL TYPE FASTON (Quickfit / release) 4.75 mm OPERATING TEMPERATURE RANGE Storage -20C to +60C Charge -15C to +50C Discharge -20C to +60C STORAGE Capacity loss per month at 20C (approx) 3 % CASE MATERIAL Standard Option ABS (UL.94:HB) Flame retardant option (FR) ABS (UL94:V0) CHARGE VOLTAGE Float charge voltage at 20C 13.65 (1%) V 2.275 (1%) V/cell Float Charge voltage temperature correction factor
(for variations from the standard 20C)-3 mV/cell/C Cyclic (or Boost) charge at 20C 14.5 (3%) V 2.42 (3%) V/cell Cyclic Charge voltage temperature correction factor
(for variations from the standard 20C)-4 mV/cell/C CHARGE CURRENT Float charge current limit No limit A Cyclic (or Boost) charge current limit 0.73 A MAXIMUM DISCHARGE CURRENT 1 minute 29 A SHORT-CIRCUIT CURRENT & INTERNAL RESISTANCE (according to EN IEC 60896-21) Internal resistance N/A m? Short-Circuit current N/A A IMPEDANCE Measured at 1 kHz 55 m? PERFORMANCE & CHARACTERISTICS Refer to the technical manual YUCEL DESIGN LIFE EUROBAT Classification: Standard Commercial 3 to 5 years Yuasa design life @ 20C up to 5 years SAFETY Installation
Can be installed and operated in any orientation except permanently invertedHandles
Batteries must not be suspended by their handles (where fitted)Vent valves
Each cell is fitted with a low pressure release valve to allow gasses to escape and then reseal.Gas Release
VRLA Batteries release hydrogen gas which can form explosive mixtures in air. Do not place inside a
sealed containerRecycling
YUASA’s VRLA batteries must be recycled at the end of life in accordance with local and national laws
and regulations - Onsite Maintenance
Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.
1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT
For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.
Warranty Plus Extends your warranty up to 3 years, next working day replacement Warranty Plus Extends your warranty up to 5 years, next working day replacement Intervention, Provides one preventative maintenance visit, planned visit Battery Plus, Provides replacement batteries to site, next working day replacement Warranty One Extends your warranty up to 1 year, next working day replacement 2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT
No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.
Services Included
Silver Level
Gold Level
Platinum Level
Technical Hotline 24/7 Yes Yes Yes Preventative Maintenance Yes Yes Yes Remote Monitoring 24/7 Yes Yes Yes Firmware Upgrades Yes Yes Yes Emergency Response Yes Yes Yes Labour Yes Yes Yes Parts Yes Yes Yes Monthly Event/Status Report option option option Onsite Crash Kit option option option Response Time 12 working hours 8 working hours 4 clock hours 3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT
Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.
Engineer Installation and configuration during normal hours 24×7 flexible status and remote monitoring. Encrypted communication, allowing safe offsite monitoring Alarms and events emailed and SMS texted automatically Firewall Friendly Cloud based status overview and multiple sites status on one screen Allows First Fix Response to Site 4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.
- Reviews (0)
Product Reviews
Company Reviews
Our brands
Shown below is a small selection of some of our customers we have helped through understanding clients challenges and implementing our unique approach to helping clients built around: listening to our clients, understanding the challenges they face and providing a range of options which compliments their requirements. Our aim is not to sell products but provide solutions with the help of our in house Power Consultants and Electricians.