Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988

Eaton 9SX 1.5kVA Power Factor Correction UPS (5 Minutes Runtime) - 9SX1500I

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups
  • Order Now. Speak to a Specialist. Call 0800 978 8988.
  • ETA will be advised upon ordering or call us.

Tailor to your needs. Speak to a Specialist.
Call: 0800 978 8988

Please email me when stock is available

Alternative Product

We have such a wide range of products that we need to discuss your requirements to give you a range of solutions best chosen to fit your needs.
Please call our team of experts on 0800 978 8988 to discus alternatives, lead-times and specifications.

The Eaton 9SX UPS offers high availability, flexibility and advanced protection for infrastructure, industrial, medical, IT, networking, storage and telecom. Delivering on-line double conversion protection in convenient tower, rack or RT format

Graphical LCD

The new graphical LCD provides clear information on the UPS’s status and measurements on a single screen (in seven languages). LCD display position can be adjusted to offer the best viewable angle for tower and rack usage.

Virtualisation-ready

With an optional network card and Eaton’s Intelligent Power® Software Suite compatible with all major OS 9SX seamlessly integrates with leading virtualisation environments and cloud orchestrations tools.

Extended runtime

Eaton 9SX UPS allows you to increase the runtime by adding external hot-swappable battery modules, able to run systems for hours if necessary. The additional battery modules are automatically recognised by the UPS.

General specifications

Product Name Eaton 9SX UPS
Catalog Number 9SX1500I
Model Code Eaton 9SX 1500i
UPC 743172090935
Product Length/Depth 16 cm
Product Height 25.2 cm
Product Width 43.7 cm
Product Weight 18.5 kg
Warranty 2 year
Compliances CE Marked
TUV
cULus Listed
CSA 22.2
FCC part 15 Class B
CISPR22 Class B
Certifications IEC/EN 62040-1
UL 1778
IEC/EN 62040-2
CE
cULus Listed
EAC
Model Code Eaton 9SX 1500i

Product specifications

Secondary frequency – max 60 Hz
Output waveform Sine wave
Max number of battery packs 4
Wattage 1350 W
Output power factor 0.9
Form factor Tower
Voltage distortion output (linear load) – max 3
Includes network card No
Input connection C14
Input voltage – min 120 V
Output voltage – max 240 V
Secondary frequency – min 50 Hz
Software compatibility Eaton Intelligent Power Manager, Eaton Intelligent Power Protector
Battery replacement Hot-swappable internal batteries and extended battery modules (EBMs)
Battery type Sealed, lead-acid
Efficiency 91.8
Special features Double conversion topology|Constantly monitors power conditions and regulates voltage and frequency|Provides more real power (watts) to protect more equipment with a 0.9 power factor|Energy efficient, reduce energy and cooling costs|Internal bypass allows service continuity in case of UPS fault|Next-generation graphical LCD display|Meter energy consumption (at the UPS level)|Hot swappable batteries|Advanced Battery Management (ABM) technology to increase battery lifetime|Long backup time with up to 4 optional EBM
Construction type Free standing model
Output voltage – min 200 V
Color Black
Extended battery capability Yes
Output voltage range 200/208/220/230/240 V +/- 2%
Topology Online/Double-conversion
BTU Rating Online: 460
Efficiency (eco-mode) 96.6
Back-up time 5.5 min
Input nominal voltage 230V default (200/208/220/230/240/250V)
Input power factor >.99
Input frequency range 40-70 Hz
Internal bypass

Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

Platinum Plus

 

Technical Hotline 24/7 Yes Yes Yes Yes Green tick
Preventative Maintenance Yes Yes Yes Yes Green tick
Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
Firmware Upgrades Yes Yes Yes Yes Green tick
Emergency Response Yes Yes Yes Yes Green tick
Labour Yes Yes Yes Yes Green tick
Parts Yes Yes Yes option Green tick
Monthly Event/Status Report option option option option Green tick
Onsite Crash Kit option option option onsite Green tick
Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
Guaranteed Fix time 4 Clock hours Green tick

3: 24×7 Remote Monitoring Contracts –

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours Green tick
24×7 flexible status and remote monitoring. Green tick
Encrypted communication, allowing safe offsite monitoring Green tick
Alarms and events emailed and SMS texted automatically Green tick
Firewall Friendly Green tick
Cloud based status overview and multiple sites status on one screen Green tick
Allows First Fix Response to Site Green tick

4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

5. Switchgear – Contact us for more information.

Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

  • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
  • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
  • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us