Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988
SKU: 5PX1500iRTN Categories: , , Brand: Eaton Tag:

Eaton 5PX 1500i RT2U Netpack - 5PX1500iRTN

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups
  • Order Now. Speak to a Specialist. Call 0800 978 8988.
  • ETA will be advised upon ordering or call us.

Tailor to your needs. Speak to a Specialist.
Call: 0800 978 8988

Please email me when stock is available

Alternative Product

We have such a wide range of products that we need to discuss your requirements to give you a range of solutions best chosen to fit your needs.
Please call our team of experts on 0800 978 8988 to discus alternatives, lead-times and specifications.

Energy efficient With an optimised electrical design and up to 99% efficiency, the 5PX is an ENERGY STAR® qualified UPS which allows you to reduce cooling and utility costs. For the first time in the industry the 5PX can meter energy consumption right down to the managed outlet groups. Graphical LCD The new graphical LCD display provides clear information on he UPS’s status and measurements on a single screen (in seven languages). Enhanced configuration capabilities are also available with easy-to-use navigation keys. Ease-of-use The plug-and-play functionality of the 5S allows you to start backing up your equipment the moment you take the unit out of the box. Gain automatic integration with Windows, Mac and Linux with a simple connection to a USB port.

Power
Output power 1350 W
Input operation voltage (min) 150 V
Input operation voltage (max) 294 V
Output operation voltage (min) 200 V
Output operation voltage (max) 240 V
Efficiency 99%
Emergency Power Off (EPO) Yes
Power factor 0.9
Output power capacity 1500 VA
ECO mode No
Performance
UPS topology Line-Interactive
Waveform Pure sine
Automatic Voltage Regulation (AVR) No
Number of output phases 1
Number of input phases 1
LED indicators Yes
Surge protection Yes
Noise level 45 dB
Features
Output frequency 50/60 Hz
UPS topology Line-Interactive
Waveform Pure sine
Automatic Voltage Regulation (AVR) No
Number of output phases 1
Number of input phases 1
Output power 1350 W
Input operation voltage (min) 150 V
Input operation voltage (max) 294 V
Output operation voltage (min) 200 V
Output operation voltage (max) 240 V
Efficiency 99%
Surge protection Yes
Emergency Power Off (EPO) Yes
Power factor 0.9
Noise level 45 dB
Output power capacity 1500 VA
ECO mode No
Input frequency 40/70 Hz
Ports & interfaces
USB port Yes
AC outlets quantity 8 AC outlet(s)
AC outlet types C13 coupler
Power plug C14 coupler
USB 2.0 ports quantity 1
RS-232 ports 1
Battery
Battery technology Sealed Lead Acid (VRLA)
Typical backup time at half load 19 min
Typical backup time at full load 3 min
Hot-swap battery Yes
Automatic battery test Yes
Design
Rack capacity 2U
Form factor Rackmount/Tower
LED indicators Yes
Product colour Black
Safety IEC/EN 62040-1-1, IEC/EN 62040-2 (EMC), IEC/EN 62040-3
Display LCD
Certification CE, CB, TV
Built-in fan Yes
Operational conditions
Operating temperature (T-T) 0 – 40 C
Technical details
Output frequency 50/60 Hz
Cooling
Built-in fan Yes
Weight & dimensions
Weight 27.6 kg
Width 441 mm
Height 86.2 mm
Depth 522 mm
Packaging data
Rack mount kit Yes
Bundled software Intelligent Power Software suite
Management card included Yes
Certificates
Safety IEC/EN 62040-1-1, IEC/EN 62040-2 (EMC), IEC/EN 62040-3
Certification CE, CB, TV
Other features
Input connection type IEC C14
Overload protection Yes
Nominal output voltage 230 V
Nominal input voltage 230 V
Mac compatibility No
Compatible operating systems Windows (x86/x64) 7 / 2008 / Vista / 2003 / XP
Windows (x86) 2000
Linux (x86/x64)
Debian GNU Linux: Lenny
SUSE/Novell: SLES 11, OpenSUSE 11.2,
Redhat Enterprise Linux: RHEL 5.4, Fedora core 12
Ubuntu: 10.04
ESX 4; ESXi 4, 4.10
Microsoft Hyper-V, Hyper V Server
Packaging content
Rack mount kit Yes
Bundled software Intelligent Power Software suite

Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

Platinum Plus

 

Technical Hotline 24/7 Yes Yes Yes Yes Green tick
Preventative Maintenance Yes Yes Yes Yes Green tick
Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
Firmware Upgrades Yes Yes Yes Yes Green tick
Emergency Response Yes Yes Yes Yes Green tick
Labour Yes Yes Yes Yes Green tick
Parts Yes Yes Yes option Green tick
Monthly Event/Status Report option option option option Green tick
Onsite Crash Kit option option option onsite Green tick
Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
Guaranteed Fix time 4 Clock hours Green tick

3: 24×7 Remote Monitoring Contracts –

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours Green tick
24×7 flexible status and remote monitoring. Green tick
Encrypted communication, allowing safe offsite monitoring Green tick
Alarms and events emailed and SMS texted automatically Green tick
Firewall Friendly Green tick
Cloud based status overview and multiple sites status on one screen Green tick
Allows First Fix Response to Site Green tick

4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

5. Switchgear – Contact us for more information.

Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

  • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
  • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
  • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.